Hyperspan Power™ UPS

From 500 VA towers to 80 kVA hall cabinets

Hyperspan Power™ uninterruptible power supplies run from a 500 VA line-interactive tower through 1 kVA, 1.5 kVA, 2 kVA and 3 kVA rack units, up to 6 kVA, 10 kVA, 20 kVA, 40 kVA and 80 kVA online cabinets. Tower units use BS 1363 outlets. Larger rack and floor units are specified with IEC inlets for comms rooms and data halls. Confirm runtime and electrical design with the project designer.

Why choose Hyperspan

Built for real-world specification

A full rating ladder

Ten models from 500 VA to 80 kVA, so a desk, a comms rack and a hall can share one Power™ family.

Honest ratings

Each SKU is named with its VA or kVA rating. Runtime depends on the connected load and is confirmed at design.

Form to match the room

Towers for the desk, 2U and 3U for the rack, floor cabinets for three-phase halls.

Sits with Power™ PDUs

Use a UPS upstream of Hyperspan Rack™ cabinets and Power™ PDUs.

Product family

Products in this range

Browse 10 products with dedicated detail pages, technical datasheets. Use Add to BOM on each product page when signed in.

Loading products…

Selection guide

Choosing the right product

Match the installation environment and performance target to the correct XR construction and CPR class.

Project requirementRecommended product
A single desk or small switch500 VA or 1000 VA tower
A workstation plus peripherals1500 VA tower
A 19-inch comms rack2 kVA or 3 kVA 2U
A comms room6 kVA or 10 kVA 3U online
A data hall20, 40 or 80 kVA floor cabinet

Ordering guide

SKUs and variants

Confirm final availability and datasheets with Hyperspan Technical Support for live projects.

Product CodeDescriptionTypeFormatApplication
HSP-UPS-500VAPower™ UPS 500 VA tower, line-interactive, BS 1363 outletsLine-interactive500 VA towerDesktop and small network gear
HSP-UPS-1000VAPower™ UPS 1000 VA tower, line-interactive, BS 1363 outletsLine-interactive1000 VA towerWorkstations and small comms
HSP-UPS-1500VAPower™ UPS 1500 VA tower, line-interactive, BS 1363 outletsLine-interactive1500 VA towerLarger tower loads
HSP-UPS-2KVA-2UPower™ UPS 2 kVA 2U rack, line-interactive, IEC C13 outlets, IEC 60309 inletLine-interactive2 kVA 2URack servers and switches
HSP-UPS-3KVA-2UPower™ UPS 3 kVA 2U rack, line-interactive, IEC C13 outlets, IEC 60309 inletLine-interactive3 kVA 2UDenser 2U rack loads
HSP-UPS-6KVA-3UPower™ UPS 6 kVA 3U rack, online double-conversion, IEC 60309 inletOnline6 kVA 3UComms room plant
HSP-UPS-10KVA-3UPower™ UPS 10 kVA 3U rack, online double-conversion, IEC 60309 inletOnline10 kVA 3ULarger comms rooms
HSP-UPS-20KVAPower™ UPS 20 kVA floor cabinet, online double-conversion, three-phaseOnline20 kVA floorSmall data halls
HSP-UPS-40KVAPower™ UPS 40 kVA floor cabinet, online double-conversion, three-phaseOnline40 kVA floorData halls
HSP-UPS-80KVAPower™ UPS 80 kVA floor cabinet, online double-conversion, three-phaseOnline80 kVA floorLarger data halls

Range at a glance

Key specifications

Product Family
Hyperspan Power™ UPS
Ratings
500 VA · 1000 VA · 1500 VA · 2 kVA · 3 kVA · 6 kVA · 10 kVA · 20 kVA · 40 kVA · 80 kVA
Topology
Line-interactive towers and small racks · online double-conversion from 6 kVA
Outlets
BS 1363 on towers · IEC on rack and floor units
Form
Tower · 2U · 3U · floor cabinet

Technical highlights

500 VA1.5 kVA3 kVA10 kVA80 kVALine-interactiveOnlineThree-phase

Typical applications

Offices
Comms Rooms
Data Centres
Labs
Retail

* The smallest model is 500 VA. The range then steps up through kVA ratings to 80 kVA.

* Runtime, battery autonomy and bypass arrangements are confirmed with the project electrical designer. They are not printed as a fixed figure on the SKU.

* Certificates of Conformity are generated per SKU. CPR DoP is not applicable to UPS units.