Hyperspan Power™
Hyperspan Power™ UPS
From 500 VA towers to 80 kVA hall cabinets
Hyperspan Power™ uninterruptible power supplies run from a 500 VA line-interactive tower through 1 kVA, 1.5 kVA, 2 kVA and 3 kVA rack units, up to 6 kVA, 10 kVA, 20 kVA, 40 kVA and 80 kVA online cabinets. Tower units use BS 1363 outlets. Larger rack and floor units are specified with IEC inlets for comms rooms and data halls. Confirm runtime and electrical design with the project designer.

Why choose Hyperspan
Built for real-world specification
A full rating ladder
Ten models from 500 VA to 80 kVA, so a desk, a comms rack and a hall can share one Power™ family.
Honest ratings
Each SKU is named with its VA or kVA rating. Runtime depends on the connected load and is confirmed at design.
Form to match the room
Towers for the desk, 2U and 3U for the rack, floor cabinets for three-phase halls.
Sits with Power™ PDUs
Use a UPS upstream of Hyperspan Rack™ cabinets and Power™ PDUs.

Product family
Products in this range
Browse 10 products with dedicated detail pages, technical datasheets. Use Add to BOM on each product page when signed in.
Loading products…

Selection guide
Choosing the right product
Match the installation environment and performance target to the correct XR construction and CPR class.
| Project requirement | Recommended product |
|---|---|
| A single desk or small switch | 500 VA or 1000 VA tower |
| A workstation plus peripherals | 1500 VA tower |
| A 19-inch comms rack | 2 kVA or 3 kVA 2U |
| A comms room | 6 kVA or 10 kVA 3U online |
| A data hall | 20, 40 or 80 kVA floor cabinet |

Ordering guide
SKUs and variants
Confirm final availability and datasheets with Hyperspan Technical Support for live projects.
| Product Code | Description | Type | Format | Application |
|---|---|---|---|---|
| HSP-UPS-500VA | Power™ UPS 500 VA tower, line-interactive, BS 1363 outlets | Line-interactive | 500 VA tower | Desktop and small network gear |
| HSP-UPS-1000VA | Power™ UPS 1000 VA tower, line-interactive, BS 1363 outlets | Line-interactive | 1000 VA tower | Workstations and small comms |
| HSP-UPS-1500VA | Power™ UPS 1500 VA tower, line-interactive, BS 1363 outlets | Line-interactive | 1500 VA tower | Larger tower loads |
| HSP-UPS-2KVA-2U | Power™ UPS 2 kVA 2U rack, line-interactive, IEC C13 outlets, IEC 60309 inlet | Line-interactive | 2 kVA 2U | Rack servers and switches |
| HSP-UPS-3KVA-2U | Power™ UPS 3 kVA 2U rack, line-interactive, IEC C13 outlets, IEC 60309 inlet | Line-interactive | 3 kVA 2U | Denser 2U rack loads |
| HSP-UPS-6KVA-3U | Power™ UPS 6 kVA 3U rack, online double-conversion, IEC 60309 inlet | Online | 6 kVA 3U | Comms room plant |
| HSP-UPS-10KVA-3U | Power™ UPS 10 kVA 3U rack, online double-conversion, IEC 60309 inlet | Online | 10 kVA 3U | Larger comms rooms |
| HSP-UPS-20KVA | Power™ UPS 20 kVA floor cabinet, online double-conversion, three-phase | Online | 20 kVA floor | Small data halls |
| HSP-UPS-40KVA | Power™ UPS 40 kVA floor cabinet, online double-conversion, three-phase | Online | 40 kVA floor | Data halls |
| HSP-UPS-80KVA | Power™ UPS 80 kVA floor cabinet, online double-conversion, three-phase | Online | 80 kVA floor | Larger data halls |

Range at a glance
Key specifications
- Product Family
- Hyperspan Power™ UPS
- Ratings
- 500 VA · 1000 VA · 1500 VA · 2 kVA · 3 kVA · 6 kVA · 10 kVA · 20 kVA · 40 kVA · 80 kVA
- Topology
- Line-interactive towers and small racks · online double-conversion from 6 kVA
- Outlets
- BS 1363 on towers · IEC on rack and floor units
- Form
- Tower · 2U · 3U · floor cabinet
Technical highlights
Typical applications
* The smallest model is 500 VA. The range then steps up through kVA ratings to 80 kVA.
* Runtime, battery autonomy and bypass arrangements are confirmed with the project electrical designer. They are not printed as a fixed figure on the SKU.
* Certificates of Conformity are generated per SKU. CPR DoP is not applicable to UPS units.

Need this range for a live project?
Share your layout, device type and longest runs and we’ll help map the correct SKUs and constructions.