Skip to content
HYPERSPAN

Downloads and Tools

Product Catalogue 2026

Digital pages · 45 / 61 · Power™ UPS — Ordering Guide

ContentsPDF download

Hyperspan Power™

POWER™ UPS — ORDERING GUIDE

UPS product codes from 500 VA to 80 kVA

Hyperspan Power™ uninterruptible power supplies run from a 500 VA line-interactive tower through 1 kVA, 1.5 kVA, 2 kVA and 3 kVA rack units, up to 6 kVA, 10 kVA, 20 kVA, 40 kVA and 80 kVA online cabinets. Tower units use BS 1363 outlets. Larger rack and floor units are specified with IEC inlets for comms rooms and data halls. Confirm runtime and electrical design with the project designer.

500 to 1500 VA towers

Line-interactive towers with BS 1363 outlets for desks and small network gear.

2 kVA and 3 kVA rack

2U line-interactive units for servers and switches.

6 kVA and 10 kVA rack

3U online double-conversion units with an IEC 60309 inlet.

20 to 80 kVA floor

Online floor cabinets for three-phase halls.

Complete Product Ordering Guide

Product codeDescriptionTypeFormatApplication
HSP-UPS-500VAPower™ UPS 500 VA tower, line-interactive, BS 1363 outlets — part of Hyperspan Power™ UPS.Line-interactive500 VA towerDesktop and small network gear
HSP-UPS-1000VAPower™ UPS 1000 VA tower, line-interactive, BS 1363 outlets — part of Hyperspan Power™ UPS.Line-interactive1000 VA towerWorkstations and small comms
HSP-UPS-1500VAPower™ UPS 1500 VA tower, line-interactive, BS 1363 outlets — part of Hyperspan Power™ UPS.Line-interactive1500 VA towerLarger tower loads
HSP-UPS-2KVA-2UPower™ UPS 2 kVA 2U rack, line-interactive, IEC C13 outlets, IEC 60309 inlet — part of Hyperspan Power™ UPS.Line-interactive2 kVA 2URack servers and switches
HSP-UPS-3KVA-2UPower™ UPS 3 kVA 2U rack, line-interactive, IEC C13 outlets, IEC 60309 inlet — part of Hyperspan Power™ UPS.Line-interactive3 kVA 2UDenser 2U rack loads
HSP-UPS-6KVA-3UPower™ UPS 6 kVA 3U rack, online double-conversion, IEC 60309 inlet — part of Hyperspan Power™ UPS.Online6 kVA 3UComms room plant
HSP-UPS-10KVA-3UPower™ UPS 10 kVA 3U rack, online double-conversion, IEC 60309 inlet — part of Hyperspan Power™ UPS.Online10 kVA 3ULarger comms rooms
HSP-UPS-20KVAPower™ UPS 20 kVA floor cabinet, online double-conversion, three-phase — part of Hyperspan Power™ UPS.Online20 kVA floorSmall data halls
HSP-UPS-40KVAPower™ UPS 40 kVA floor cabinet, online double-conversion, three-phase — part of Hyperspan Power™ UPS.Online40 kVA floorData halls
HSP-UPS-80KVAPower™ UPS 80 kVA floor cabinet, online double-conversion, three-phase — part of Hyperspan Power™ UPS.Online80 kVA floorLarger data halls

Runtime depends on the connected load and is confirmed at design. Online models are double-conversion from 6 kVA.

Product selection guide

A single desk or small switch

500 VA or 1000 VA tower

A workstation plus peripherals

1500 VA tower

A 19-inch comms rack

2 kVA or 3 kVA 2U

A comms room

6 kVA or 10 kVA 3U online

A data hall

20, 40 or 80 kVA floor cabinet

Range at a glance

Product Family
Hyperspan Power™ UPS
Ratings
500 VA · 1000 VA · 1500 VA · 2 kVA · 3 kVA · 6 kVA · 10 kVA · 20 kVA · 40 kVA · 80 kVA
Topology
Line-interactive towers and small racks · online double-conversion from 6 kVA
Outlets
BS 1363 on towers · IEC on rack and floor units
Form
Tower · 2U · 3U · floor cabinet

Technical highlights

500 VA
1.5 kVA
3 kVA
10 kVA
80 kVA
Line-interactive
Online
Three-phase